Uncover the secrets: how to jumper thermostat for ac like a pro

Rob is a seasoned home improvement writer with over 15 years of experience researching and recommending products for the home. Prior to starting Nurturing Homeaid, he wrote extensively for This Old House magazine and has been featured as a home expert on several TV and radio programs. An avid DIY-er,...

What To Know

  • This detailed guide will walk you through the process of jumpering a thermostat for AC, ensuring that you can effectively bypass the thermostat and get your AC up and running again.
  • Jumpering is a technique used to bypass the thermostat by creating a direct connection between two terminals on the thermostat’s control board.
  • Strip the ends of the wire and connect one end to the “R” terminal and the other end to the “Y” or “W” terminal.

When the scorching summer heat strikes, a malfunctioning air conditioner can turn your home into an unbearable oven. One common issue that can disrupt your AC’s operation is a faulty thermostat. If you find yourself in this predicament, jumpering the thermostat may provide a temporary solution to restore some semblance of coolness.

This detailed guide will walk you through the process of jumpering a thermostat for AC, ensuring that you can effectively bypass the thermostat and get your AC up and running again.

Understanding Jumpering

Jumpering is a technique used to bypass the thermostat by creating a direct connection between two terminals on the thermostat’s control board. This connection effectively tricks the AC into thinking that the thermostat is calling for cooling, regardless of the actual temperature.

Safety Precautions

Before embarking on any electrical work, it is imperative to take the following safety precautions:

  • Turn off the power to the AC unit at the breaker panel.
  • Wear insulated gloves and safety glasses.
  • Use a non-contact voltage tester to ensure that the power is indeed off.

Identifying the Thermostat Terminals

The terminals on the thermostat control board are typically labeled with letters or symbols. The terminals you need to jumper will vary depending on your specific thermostat model. Refer to the thermostat’s user manual or consult a qualified HVAC technician for precise guidance.

Jumpering the Thermostat

1. Remove the Thermostat Face: Gently pull on the thermostat face to detach it from the baseplate.
2. Locate the Control Board: The control board is usually located behind the thermostat face.
3. Identify the Terminals: Find the terminals labeled “R” and “Y” or “W” (depending on your thermostat model).
4. Create the Jumper: Cut a short piece of insulated wire (approximately 1-2 inches).
5. Connect the Jumper: Strip the ends of the wire and connect one end to the “R” terminal and the other end to the “Y” or “W” terminal.
6. Reassemble the Thermostat: Carefully place the thermostat face back onto the baseplate.

Testing the AC Unit

1. Turn on the Power: Restore power to the AC unit at the breaker panel.
2. Set the Thermostat Temperature: Set the thermostat to a temperature below the current room temperature.
3. Observe the AC Unit: The AC unit should start running after a few minutes.

Troubleshooting Common Issues

  • AC Unit Not Running: Ensure that the jumper is properly connected and that the power is turned on.
  • AC Unit Running Continuously: Remove the jumper and reset the thermostat to its normal operating mode.
  • AC Unit Blowing Warm Air: Check the refrigerant levels and ensure that the condenser coils are clean.

When to Call a Professional

Jumpering a thermostat is a temporary solution. If the AC unit continues to malfunction after jumpering, it is advisable to contact a qualified HVAC technician for further diagnosis and repair.

Frequently Asked Questions

Q: Is it safe to jumper a thermostat?

A: Yes, jumpering a thermostat is generally safe as long as proper safety precautions are followed.

Q: How long can I leave a thermostat jumped?

A: Jumpering a thermostat should only be a temporary solution. It is recommended to have it repaired or replaced as soon as possible.

Q: Will jumpering a thermostat damage my AC unit?

A: No, jumpering a thermostat will not damage your AC unit if done correctly. However, leaving it jumped for an extended period may put unnecessary strain on the system.

Q: Can I jumper a thermostat for heating?

A: Yes, you can also jumper a thermostat for heating by connecting the “R” and “W” terminals.

Q: What if I don’t know which terminals to jumper?

A: Refer to the thermostat’s user manual or consult a qualified HVAC technician for guidance.

Was this page helpful?

Rob Sanders

Rob is a seasoned home improvement writer with over 15 years of experience researching and recommending products for the home. Prior to starting Nurturing Homeaid, he wrote extensively for This Old House magazine and has been featured as a home expert on several TV and radio programs. An avid DIY-er, Rob takes pride in testing out the latest tools and gadgets to see how they can make home projects easier. When it comes to heating systems, he's evaluated over 50 different furnace and boiler models over the years. Rob founded Nurturing Homeaid with his business partner Jim in 2020 to provide homeowners with genuine product recommendations they can trust. In his free time, Rob enjoys remodeling old homes with his family and traveling to visit architectural landmarks across the country. He holds a bachelor's degree in Journalism from Syracuse University.